BodyParts3D, © The Database Center for Life Science licensed under CC Attribution-Share Alike 2.1 Japan. Source STL mirror: https://github.com/Kevin-Mattheus-Moerman/BodyParts3D License: https://creativecommons.org/licenses/by-sa/2.1/jp/ This GLB is an adaptation of the source STL meshes and is distributed under the same license. Modifications: one shared rigid orientation/translation, vertex deduplication, smooth vertex normals and GLB packaging. No per-bone scaling, resizing or repositioning. Original millimetre scale retained. GLB positions stored in metres; the viewer applies a shared 1000 multiplier to display millimetres. Mitsuhashi N et al. BodyParts3D: 3D structure database for anatomical concepts. Nucleic Acids Research 2009;37:D782–D785. https://doi.org/10.1093/nar/gkn613 Full-body background display uses available original shared-frame skeletal surfaces. It is not an exhaustive 206-bone teaching inventory. vizJET adaptations: shared translation, rotation, uniform display scale and tissue materials; selection, region filters and visibility controls. The native 171 reference surfaces retain their original shared positions. Missing left digital phalanges and the left foot navicular are reflected from right reference bones across the dataset median plane; these are explicitly schematic bilateral reconstructions, not independent scanned anatomy. No cartoon skull or procedural pelvis is used. Current official database license: https://dbarchive.biosciencedbc.jp/en/bodyparts3d/lic.html (2025-02-27), CC Attribution 4.0 International. The existing derivative GLB attribution above is preserved. bone-details.glb: lossless subset export of FMA24474 (right femur) and FMA13074/FMA13075 (L3/L4). vizJET clips the reference femur geometrically to a coronal half and derives its displayed cut contour from triangle-plane intersections. Cortical thickness, marrow, trabecular microarchitecture, intervertebral disc layers, cartilage and remodeling cells are teaching reconstructions, not measured histology from this reference subject. Bone-anatomy overlays: periosteal and articular patches follow the retained reference shell. Nutrient vessels, growth plates/epiphyseal lines, marrow distribution, tissue thickness and region boundaries are didactic reconstructions. Growth mode uses the same adult reference outer surface; it is not a paediatric specimen. Articular patches omit periosteum. Bone Explorer adds selectable tissue layers and independent red/yellow marrow volumes, whole-femur viewing, a movable transverse clipping plane and a magnified view of the corresponding native triangle-plane intersection. Reconstructed marrow and cortical thickness within the inset are schematic; the outer transverse contour is measured from the reference mesh. Growth-zone and marrow microviews are educational reconstructions. Relative microscopic scale and developmental timing are illustrative. Color overlays distinguish axial/appendicular anatomy and rib pairs 1–7, 8–10 and 11–12. Costal cartilage paths and the common costal arch are schematic connectors between reference bones, not additional measured meshes. Stapes and coccyx annotations indicate anatomical regions and normal counts; these structures remain absent from the reference bone set. Stammatlas / trunk-atlas.json (2026-10-19): BodyParts3D 4.0, PART-OF OBJ 99 archive, acquired directly from DBCLS / LSDB Archive. Source: https://dbarchive.biosciencedbc.jp/data/bodyparts3d/LATEST/partof_BP3D_4.0_obj_99.zip . BodyParts3D, © The Database Center for Life Science. Original mesh headers specify CC Attribution-Share Alike 2.1 Japan; the retained geometry and adapted learning-region masks are made available under that license. The current official archive license page (updated 2025-02-27) specifies CC Attribution 4.0 International: https://dbarchive.biosciencedbc.jp/en/bodyparts3d/lic.html . 52 bone models, 23 intervertebral discs and 14 costal cartilages; 323,036 original triangles. A shared rigid coordinate transform and uniform scale only; original per-part positions and triangle connectivity retained. The three original sternal elements are concatenated into one sternum model. The generically catalogued disc FMA10446 is labelled Th12/L1 according to its original shared-frame position between those vertebrae; it is an original mesh, not a reconstructed disc. 59 landmark regions and four joint-contact regions are approximate educational selections. Typical vertebral markers are limited to C4, Th6 and L3; typical rib markers to the sixth pair. The source lacks coccyx and costal cartilages VIII–XII. No procedural substitutes are displayed for them. Stamm detail curriculum update: 122 contextual syllabus goals in 13 areas, linked to 831 approximate landmark instances plus the retained 52 bone, 37 cartilage and four joint entries. The 89 native meshes and all triangle indices are unchanged. Detail regions cover Atlas, Axis and C3-L5, applicable rib levels, sacrum and sternum. These selections are educational localization masks, not independently measured anatomical segmentations. Small unmarked regions remain explicit learning cards. The median sacral crest is rendered as a narrow path on original surface coordinates. Variants at T9/T10 and rib X are explained in the curriculum; facets absent by normal regional anatomy (transverse costal facets at T11/T12, typical tubercles at ribs XI/XII) are not fabricated. The source does not include coccyx or coccygeal horns. Physiological curvature and scoliosis concepts are learning cards; no pathological spine deformation is presented as a measured specimen. Anatomical teaching references: UAMS Department of Neuroscience, bone tables of the back region and thorax; NCBI Bookshelf / StatPearls chapters on cervical, thoracic and lumbar vertebrae, sacrum, ribs and coccyx. Exact URLs are retained in assets/trunk-curriculum.json. Atlas / Axis detail viewer (2026-10-20): atlas-axis.json is a lossless indexed adaptation of FMA12519.stl (6172 triangles) and FMA12520.stl (6870 triangles) from the retained BodyParts3D public STL mirror. Source: https://github.com/Kevin-Mattheus-Moerman/BodyParts3D/tree/master/assets/BodyParts3D_data/stl . Copyright DBCLS; CC BY-SA 2.1 Japan. Original STL files retained in scripts/reference-atlas-axis with SHA-256 recorded per model in atlas-axis.json. Single shared rigid orientation/translation and uniform scale, vertex deduplication and smooth normals only. No per-bone geometric registration, scale or repositioning is applied to displayed geometry. The 38 regional educational masks are transferred from the existing annotations using normalized per-bone coordinates solely for selecting vertices, then localized on the untouched source mesh. This label-transfer step is approximate; boundaries are not independently segmented or clinically validated. No subdivision is claimed as anatomical resolution. No synthetic pores, fractures or microscopic architecture. This is a representative database exemplar, not a new high-resolution scan. Anatomical reference: Craniovertebral junction 360 degrees: A combined microscopic and endoscopic anatomical study, https://pmc.ncbi.nlm.nih.gov/articles/PMC5111321/ . C1/C2 integration correction (2026-10-20): Atlas and Axis use the normal trunk viewer and existing mesh objects. The former standalone URL redirects to trunk.html. Exactly twelve Atlas and fourteen Axis landmark names are retained; bilateral regions are merged. Non-requested C2 pedicle/lamina and spinal-canal marker instances are omitted from these bone-specific lists. Fine original STL geometry is used only in isolated views; the original trunk geometry and corresponding masks are restored for the assembled view, so different source frames are never mixed. Both geometry variants remain unchanged source surfaces. The revised trunk data contains 814 landmarks and 907 total entries. Frontal/maxillary teaching update (2026-10-21): Eight frontal and ten maxillary landmark entries replace seventeen prior unilateral variants. All 22 skull meshes retain the same original vertices and triangles. Detail framing always includes the entire visible frontal bone, maxilla or mandible; automatic mandibular half clipping is removed. Medial mandibular structures use an oblique whole-bone orientation. Model opening is disabled in these focused detail contexts. The skull atlas contains 81 landmarks, 22 bones and four sutures; the curriculum contains 157 goals. New fine landmarks, orbital margins and the intermaxillary suture are approximate educational surface regions, not independently measured segmentations. The frontal and maxillary sinuses and mandibular canal remain explicit location projections over intact source surfaces. They are never presented as visible open cavities. Surface/cavity visibility and Latin vocabulary are explained in original German teaching bullets. Anatomical references: UAMS Head and Neck bone tables; StatPearls Frontal Bone (NBK535424) and Maxilla (NBK538527); Haładaj et al., Anatomical Variations of the Supraorbital and Supratrochlear Nerves (2019), https://pmc.ncbi.nlm.nih.gov/articles/PMC6647930/ . Exact source links are retained in skull-curriculum.json. Ethmoid, sphenoid and temporal update (2026-10-21): The normal skull viewer now contains eight ethmoid, twenty sphenoid and fifteen temporal teaching entries per side, each with original German descriptions, visibility status and vocabulary. The skull data contains 121 landmarks, 22 unchanged source bones and four sutures; the curriculum has 161 goals. All original vertex coordinates and triangle connectivity remain unchanged. Ethmoid orientation shows the surrounding original nasal, maxillary, frontal, sphenoid, vomer, palatine, lacrimal and inferior-conchal bones in their shared frame. Context surfaces are translucent, excluded from target picking, and can be hidden as complete neighboring bones for a lateral nasal view; the selected ethmoid is never cut. The inferior nasal concha is explicitly a separate bone. Air-cell group locations, mastoid air cells, middle/inner ear regions and internal carotid/sphenoidal sinus spaces are educational location projections on intact surfaces. Individual chambers, labyrinth geometry, fine neural foramina and their true inner contours are not independently segmented or newly reconstructed. Small surface regions and foraminal rims are approximate and not clinically validated. The presence of a marker does not assert scan-level resolution. Sources: StatPearls Ethmoid Bone (NBK544328) and Sphenoid Bone (NBK544308), University of Iowa temporal bone dissection protocols, UAMS head/neck bone tables and Texas Tech University bone tables. Exact links are retained in skull-curriculum.json. Os occipitale: eleven teaching regions on the unchanged complete source bone. Nuchal line trajectories are narrow surface approximations, not independently segmented crests. Hypoglossal canal portals are localized; the canal interior is not reconstructed. Os sacrum detail update: sixteen curated teaching regions on unchanged original geometry. Bilateral landmarks share one entry. Sacral canal localization marks native entry/outlet regions, not an independently segmented interior. Fine reliefs and aperture boundaries remain educational approximations. Sacrum detailed surface (single-bone view): My Segmenter, NIH 3D 3DPX-016830 version 3, https://3d.nih.gov/entries/16830 , CC BY 4.0 https://creativecommons.org/licenses/by/4.0/ . Native output mysegmenter_sacrum-nih3d.stl, 173,748 triangles. The source mesh is retained without synthetic holes, crests, smoothing or anatomical deformation; only axes, translation and uniform display scale change. Sixteen surface teaching regions are newly curated approximations. Individual variation and CT acquisition stair steps remain. The assembled trunk retains its original shared-frame BodyParts3D sacrum. Sternum teaching update: exact nine requested entries on the unchanged complete three-part source mesh. Paired notches share an entry. Costal contact regions are localized relative to the retained native rib cartilages; fine margins remain approximations. The manubriosternal angle uses a narrow surface-attached color path. Atlas retains its original detailed surface and twelve curated landmarks, now directly accessible as a single bone in the normal trunk viewer. Current curated trunk atlas: 794 landmarks, 887 total entries; includes nine sternum and twelve Atlas details. Typical rib update: right Costa VI retains the unchanged complete BodyParts3D mesh. Twelve teaching regions include the entire Os costale, head/neck/tubercle/body, local facets, groove, angle and three narrow surface crests. Fine crests and facet boundaries remain approximate teaching localizations. Axis remains its unchanged retained native isolated surface with fourteen curated landmarks. Current trunk atlas: 796 landmarks, 889 entries; curriculum: 124 goals. Anatomical terminology and classification references: OpenStax, The Thoracic Cage, https://openstax.org/books/anatomy-and-physiology-2e/pages/7-4-the-thoracic-cage ; FIPAT/IFAA Terminologia Anatomica Humana, crista corporis costae, https://ifaa.unifr.ch/Public/TNAEntryPage/auto/unit/LAEN/TAH868%20Unit%20EN.htm . Knee ligament module (2026-10-23): Z-Anatomy project models, distributed by Lluís Vinent Juanico, adapted from BodyParts3D / DBCLS. Source: https://github.com/LluisV/Z-Anatomy/tree/PC-Version/Resources/Models/FBX . License: Creative Commons Attribution-ShareAlike 4.0 International, https://creativecommons.org/licenses/by-sa/4.0/ . Sixteen named native right-knee surfaces are retained in their common transformed world frame; source FBX SHA-256 hashes are in scripts/reference-knee/native-knee.json and knee-atlas.json. Bones and menisci are context; fourteen selectable teaching entries comprise the requested bands, retinacula and MCL regions. Ligamentum patellae and the anterior/posterior meniscofemoral ligaments (Humphrey/Wrisberg) are newly authored anatomical teaching reconstructions anchored to native context. They are not separately segmented or patient-specific surfaces; their derived geometry is distributed under the same CC BY-SA 4.0 license. Both variable meniscofemoral bands are shown together for teaching. MCL anterior/posterior are AP surface masks across the native superficial/deep complex, not independently segmented fiber bundles and not synonyms for superficial/deep. Anatomy reference: NCBI Bookshelf, Knee, https://www.ncbi.nlm.nih.gov/books/NBK570163/ ; meniscofemoral relationships: https://pmc.ncbi.nlm.nih.gov/articles/PMC4877346/ . Calcaneus / Talus teaching regions (2026-10-23) 28 educational detail entries on unchanged existing right-foot BodyParts3D meshes. 13 Calcaneus and 15 Talus structures. Surface masks are approximate localizations, not separate segmentations or new high-resolution bone geometry. Sinus tarsi is shown through its two complete bony boundaries, without a solid replacement mesh. Sources and regeneration: scripts/README-hindfoot.md; scripts/curate-hindfoot.py. Calcaneus / Talus region correction (2026-10-23) Explicit side-aware surface regions replace spatial ellipsoid marks. Sulcus calcanei is separated from posterior and middle talar articular regions. Two linear subdivisions of the native triangles improve color boundary detail without altering bone shape, area, volume or alignment. This adds no scan detail. Original BodyParts3D / DBCLS license and attribution above remain applicable. Reproducible original meshes and region audit: scripts/reference-hindfoot/. Anatomical references and model limits: scripts/README-hindfoot.md. Os ilium / complete right hip context (2026-10-23) Native Os coxae dextrum, FMA16586: BodyParts3D, © The Database Center for Life Science (DBCLS), CC BY-SA 2.1 Japan. Distribution mirror: Kevin-Mattheus-Moerman / BodyParts3D, assets/BodyParts3D_data/stl/FMA16586.stl on GitHub. 9,716 native triangles retained. Adaptations: axis alignment, uniform scale, centering and 21 educational entries (ilium plus 20 requested details). The adult fused hip remains complete; ilium boundaries and fine surface paths are teaching approximations, not independently segmented or validated anatomy. Original STL and build script: scripts/reference-ilium/; scripts/build-ilium.py. Sources, interpretation and verification: scripts/README-ilium.md. Scapula and intrinsic ligaments (2026-10-27) Native right scapula FMA13395: BodyParts3D, © The Database Center for Life Science (DBCLS), CC BY-SA 2.1 Japan. Distribution mirror: Kevin-Mattheus-Moerman / BodyParts3D, assets/BodyParts3D_data/stl/FMA13395.stl on GitHub. 56,630 welded native vertices and 113,256 original triangles retained without cuts or shape changes. Adaptations: axis alignment, centering, uniform scale and educational surface regions. All three intrinsic ligaments are anatomical learning reconstructions anchored to this original bone, not segmented tissue. No artificial osseous foramen is introduced. Adapted geometry and reconstruction meshes retain CC BY-SA 2.1 Japan attribution and licensing. Original source: scripts/reference-scapula/FMA13395.stl. Regeneration: scripts/build-scapula.py. Sources and limits: README-scapula.md. Clavicula (2026-10-27) Native right clavicle FMA13322: BodyParts3D, © The Database Center for Life Science (DBCLS), CC BY-SA 2.1 Japan. Distribution mirror: Kevin-Mattheus-Moerman / BodyParts3D, assets/BodyParts3D_data/stl/FMA13322.stl on GitHub. 2,558 native welded vertices and 5,112 triangles retained, with no cuts or invented anatomy. Adaptations: rigid axis alignment, centering, uniform scale and 11 educational entries (bone plus ten details). Fine region boundaries remain approximations; the common coracoclavicular attachment includes the conoid tubercle and trapezoid line. No actual ligament or extra tubercle added. Original STL: scripts/reference-clavicle/FMA13322.stl. Regeneration: scripts/build-clavicle.py. Sources/limits: README-clavicle.md. Radius dexter FMA23464: BodyParts3D / DBCLS, CC BY-SA 2.1 Japan. Source: https://raw.githubusercontent.com/Kevin-Mattheus-Moerman/BodyParts3D/master/assets/BodyParts3D_data/stl/FMA23464.stl. Adaptations: orientation, scale and approximate educational surface markings. Ulna dextra FMA23467: BodyParts3D / DBCLS, CC BY-SA 2.1 Japan. Native right ulna with 1,798 welded vertices and 3,592 triangles. Source: https://raw.githubusercontent.com/Kevin-Mattheus-Moerman/BodyParts3D/master/assets/BodyParts3D_data/stl/FMA23467.stl . Adaptations: axis alignment, centering, uniform scaling, and approximate educational surface localizations. Narrow border/crest marks color the original surface. No new bone geometry is introduced. License: https://creativecommons.org/licenses/by-sa/2.1/jp/ . Fine landmark boundaries are not clinically validated. Humerus dexter FMA23130: BodyParts3D / DBCLS, CC BY-SA 2.1 Japan. Native right humerus with 8,136 welded vertices and 16,268 original triangles. Source: https://raw.githubusercontent.com/Kevin-Mattheus-Moerman/BodyParts3D/master/assets/BodyParts3D_data/stl/FMA23130.stl . Adaptations: axis alignment, centering, uniform scaling and approximate educational surface localizations. Original shape and topology preserved. Fine landmarks and articular boundaries are not clinically validated segmentations. Humerustorsion is illustrated as the relationship between head and distal epicondyles, without measuring an individual angle or altering the bone. License: https://creativecommons.org/licenses/by-sa/2.1/jp/ . Sternoclavicular motion scene: BodyParts3D / DBCLS native STL frame, CC BY-SA 2.1 Japan. Original bones preserved: FMA13322, FMA13323, FMA13395, FMA7486, FMA7487, FMA7488, FMA7857, FMA7882, FMA7909, FMA7987, FMA8012, FMA8039, FMA9165, FMA9187, FMA9209. Native cartilages FMA7875, FMA7886, FMA7913, FMA8005, FMA8031, FMA8058 retain their largest connected component to remove tiny detached source artifacts. Per-source hashes/counts and one common transform are included in sternoclavicular-atlas.json. Source URL base: https://raw.githubusercontent.com/Kevin-Mattheus-Moerman/BodyParts3D/master/assets/BodyParts3D_data/stl/ . Discus articularis and all four SC ligaments are anatomical reconstructions anchored to native surfaces, not individually segmented soft tissues. Joint-face regions are approximate. The animation is an illustrative coordinated kinematic model, not patient-specific measured motion, ligament strain or force simulation. License: https://creativecommons.org/licenses/by-sa/2.1/jp/ . Acromioclavicular joint: native BodyParts3D / DBCLS shoulder-girdle bones reuse the original common-frame sternoclavicular-atlas.json scene without shape changes (CC BY-SA 2.1 Japan). Coracoclavicular complex is represented by its conoid and trapezoid meshes, not a third extra ligament. Conoid/trapezoid and upper/lower AC capsular band surfaces are explicit anatomical reconstructions anchored to native vertices. The disc is an incomplete superior meniscoid example; its presence/form varies and it is not a universal complete plate. Facet regions, tissue forms and isolated AC compensation kinematics are approximate educational representations. No patient-specific normal range, force or strain is measured. See acromioclavicular-atlas.json and scripts/README-acromioclavicular.md for dependencies and sources. License: https://creativecommons.org/licenses/by-sa/2.1/jp/ . Glenohumeral joint addition (2026-10-28) Native BodyParts3D / DBCLS common shoulder scene reused unchanged; full native right humerus FMA23130 added in the same original STL frame, preserving all vertices/connectivity. Native source SHA256 and scene SHA256 recorded in assets/glenohumeral-atlas.json. CC BY-SA 2.1 Japan applies to this adaptation. Glenoid/head marks are curated learning localizations. Labrum, superior/middle/ inferior capsular bands, axillary pouch and two coracohumeral fiber surfaces are explicit teaching reconstructions, not patient-specific tissue segmentations. Movement uses an approximate head center with a fixed scapula reference; angles and tissue wrapping are illustrative, not normal-maximal ranges or force/strain calculations. See scripts/README-glenohumeral.md for references and validation. Cubital joint addition (2026-10-28) BodyParts3D / DBCLS native right Humerus FMA23130, Radius FMA23464 and Ulna FMA23467, CC BY-SA 2.1 Japan. Complete original meshes in one original STL frame, preserving all vertices/connectivity. Source paths, hashes and transform recorded in assets/cubital-atlas.json. Joint-surface regions are curated learning approximations, reused from the native bone atlases. The total-joint highlight is the union of the three sub-joint surface regions. Cartilage, capsule and annular ligament are not separately segmented. Fixed-humerus flexion and fixed-ulna forearm rotation illustrate movement; axes, angular sweep and roll/slide are simplified and not measured individual/maximal normal ranges. Full forearm movement shows distal radioulnar participation as orientation context. See scripts/README-cubital.md for sources and validation. Elbow ligament and distal forearm/wrist addition (2026-10-28) BodyParts3D / DBCLS, CC BY-SA 2.1 Japan. Complete native right radius/ulna, eight carpals and five metacarpals share the original STL frame; all original bone shapes/topology retained. New source STLs in scripts/reference-wrist; SHA256/counts/common transform in assets/forearm-wrist-atlas.json. Elbow bones unchanged. Ringband, ulnar collateral three-part complex, radial collateral, forearm membrane/fiber arrows, chord, triangular disc and broad wrist bands are explicit anatomical teaching reconstructions. Arrows indicate main fiber course, not muscle action. Wrist band regions are coarse and variable; ulnocarpal origins refer to approximate TFCC/capsular areas near styloid, not uniform direct osseous insertions. Simplified fixed-ulna forearm rotation and rigid hand-block radiocarpal motion do not simulate true midcarpal individual bone motion, force or patient-specific maximal ranges. Full TFCC, capsule and cartilage are not separately segmented. See README-cubital.md and README-forearm-wrist.md for sources and validation. Mediocarpal joint addition (2026-10-28) BodyParts3D / DBCLS CC BY-SA 2.1 Japan: the 13 original whole right carpal and metacarpal bones are reused unchanged. Source-atlas and per-STL hashes in assets/mediocarpal-atlas.json. Paired native-surface teaching masks mark the compound S-shaped midcarpal interface; pisiform excluded from this joint. Pisohamate/pisometacarpal bands, dorsal arcuate, palmar radiate and general palmar/interosseous/dorsal intercarpal areas are coarse reconstructed regions. Named/general groups reuse the same physical band meshes without duplication. Variable insertions and individual fiber boundaries are not clinically segmented. Extension is a limited illustrative rigid distal-row/metacarpal movement with proximal row/pisiform held as reference, not a true physiological fixed-axis or patient-specific complete carpal simulation. No maximal normal ranges, mechanical band forces or strains claimed. Exact MedUni learning-list classification and functional-hinge explanation are both disclosed. See scripts/README-mediocarpal.md for sources and validation. Sphenoid whole-skull examination context (2026-11-01) All 22 existing BodyParts3D / DBCLS skull meshes and all original landmark masks unchanged. CC BY-SA 2.1 Japan. The twenty sphenoid landmarks gain whole-skull orientation metadata and an assembled, opaque, skullcap-removed teaching view. Reversible clipping hides only triangles above the existing Y=.45 cap plane, retaining every original sphenoid triangle; no additional bone, sinus or foramen geometry is fabricated. Explicit neighbor ghosting is a labeled optional learning aid. Sphenoidal sinus remains a hidden cavity with a surface location projection, not an exposed segmented sinus. Standard whole-bone isolated view remains available. See README-skull-details.md. Sphenoid region 19 and portal-mark correction (2026-11-01) All original skull bone vertices/triangles unchanged. Three paired foramina (rotundum, ovale, spinosum) now use narrow original-surface shader bands derived from closed plane/triangle intersection contours at the modeled canal walls. Native edge IDs and section levels are recorded with each feature. Former ellipsoidal patch masks replaced; holes remain unfilled. Side-separator flags prevent a line across the midline. Portal labels attach to a real opening rather than a bilateral center. This is a teaching localization on the retained source model, not independent clinical segmentation of every canal. Geometry and adaptations retain CC BY-SA 2.1 Japan. See README-skull-details.md. Lower-extremity joint curriculum (2026-11-22): Hip context retains native complete BodyParts3D right os coxae and femur surfaces. The femur is uniformly registered into an educational articulated context, with the transform recorded in hip-atlas.json. Hip labrum, iliofemoral/ischiofemoral/pubofemoral ligament courses, zona orbicularis, ligamentum capitis femoris and transverse acetabular ligament are explicit educational reconstructions, not independently segmented soft tissues. Reference: PMID 24293171, PMID 22371607, PMID 24777682; NCBI Bookshelf NBK526019. Existing native Z-Anatomy knee bones and menisci are preserved. Hoffa's infrapatellar fat pad is an explicitly simplified reconstruction (PMID 32159227). MCL portion meshes display subsets of the original pedagogic anterior/posterior masks. Single-bone nonosseous structure grading uses labeled neighboring-location projections, never a claim of direct bone insertion. Existing source licenses and attributions above remain applicable.